Wholesale Outdoor Coolroom - MTC-5060 Operation Instruction – Fland

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the value for our customers for Walk In Chiller Rooms , Cooling Storage Room , Cold Room Storage Facilities , On account of superior excellent and aggressive rate , we will be the sector leader, make sure you don’t hesitate to contact us by cellular phone or email, if you're fascinated in al any of our items.
Wholesale Outdoor Coolroom - MTC-5060 Operation Instruction – Fland Detail:

To measure, display and control the temperature; Calibrate the temperature value; Control and output the refrigerating, and defrosting; Alarm when temperature exeeds setting temp. range or when sensor error.

Specification and Size:

◊Front panel size: 100(L) x 51(W)(mm)

◊Product size: 100(L) x 51(W) x 82.S(D)(mm)

Installing hole size: 92(L) x 44(W)(mm)
Sensor wire lenth: 2 meters (probe included)
Accuracy: 土1℃
Display resolution: 0.1
Relay output contact capacity: 3A/110VAC ◊Sensor type: NTC sensor(1 OK0.125℃, B value3435K)
Operating temperature: O℃~60℃ ◊Relative humidity: 20%~85% (No condensate)
Instruction of the Keys and indicator lights on the panel:
About display screens
Room Temp.: to display the measuring temperature and the relative parameter code during setting procedure.

Set Temp.: to display the temperature when compressor stops working and the parameter change during
setting procedure.

About indicator lights
◊on temp.: Temp. when controller on
◊off temp.: Temp. when controller off. ◊Comp. delay: Compressor output delay when start or stop
◊def. cycle: Defrosting cycle time
◊def. time: Defrosting estimated time
◊max evap. temp.: Defrosting stop temp. ◊ *: Refrigerant
◊* Defrost
About indicator lights
◊on temp.: Temp. when controller on
◊off temp.: Temp. when controller off.
◊Comp. delay: Compressor output delay when
Temp.”display screen appears”F1″item, the system enters the system menusetting mode, then to page down and check all the parameter items by repeatedly pressing”SET”key. After entering the system menu, press”Ji.·and”T”key to modify the parameter value in the”Set Temp.”display screen, all the parameter indicator lights are off at this time

Under running status, press and hold”SET”key for 3s until the”on temp. “indicator light on, you can page down and check all the parameter items by repeatedly pressing”SET”key, and the parameter indicator light on with the accordingly parameter item is chosen. Under parameter checking mode, the parameter cannot be modified. If hold pressing the”SET”key for 3s or no key operations within 10s, system exit from the parameter checking mode, in the”Room Temp.”display screen, it appears the current storage temperature


Product detail pictures:

Wholesale Outdoor Coolroom - MTC-5060 Operation Instruction  – Fland detail pictures

Wholesale Outdoor Coolroom - MTC-5060 Operation Instruction  – Fland detail pictures

Wholesale Outdoor Coolroom - MTC-5060 Operation Instruction  – Fland detail pictures


Related Product Guide:

With our leading technology as well as our spirit of innovation,mutual cooperation, benefits and development, we will build a prosperous future together with your esteemed company for Wholesale Outdoor Coolroom - MTC-5060 Operation Instruction – Fland , The product will supply to all over the world, such as: Indonesia, Holland, Bulgaria, Many years of work experience, we have realized the importance of providing good quality products and whole heartedly before-sales and after-sales services. problems between suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question things they do not understand. We break down those barriers to ensure you get what you want to the level you expect, when you want it. faster delivery time and the product you want is our Criterion .
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Yannick Vergoz from Greenland - 2018.08.12 12:27
    It is really lucky to meet such a good supplier, this is our satisfied cooperation, I think we will work again!
    5 Stars By Sabrina from Irish - 2018.11.11 19:52
    Write your message here and send it to us