Our personnel are generally within the spirit of continuous improvement and excellence, and using the excellent high quality goods, favorable rate and superior after-sales expert services, we try to win every customer's believe in for Walk In Freezer Room , Cooling Storage Room , Fish Cold Storage Room , Making the Products of High Quality is the eternal goal of our company. We make unremitting efforts to realize the goal of We Will Always Keep in Pace with the Time.
Factory Cheap Cold Room Chamber - MTC-5060 Operation Instruction – Fland Detail:

To measure, display and control the temperature; Calibrate the temperature value; Control and output the refrigerating, and defrosting; Alarm when temperature exeeds setting temp. range or when sensor error.

Specification and Size:

◊Front panel size: 100(L) x 51(W)(mm)

◊Product size: 100(L) x 51(W) x 82.S(D)(mm)

Installing hole size: 92(L) x 44(W)(mm)
Sensor wire lenth: 2 meters (probe included)
Accuracy: 土1℃
Display resolution: 0.1
Relay output contact capacity: 3A/110VAC ◊Sensor type: NTC sensor(1 OK0.125℃, B value3435K)
Operating temperature: O℃~60℃ ◊Relative humidity: 20%~85% (No condensate)
Instruction of the Keys and indicator lights on the panel:
About display screens
Room Temp.: to display the measuring temperature and the relative parameter code during setting procedure.

Set Temp.: to display the temperature when compressor stops working and the parameter change during
setting procedure.

About indicator lights
◊on temp.: Temp. when controller on
◊off temp.: Temp. when controller off. ◊Comp. delay: Compressor output delay when start or stop
◊def. cycle: Defrosting cycle time
◊def. time: Defrosting estimated time
◊max evap. temp.: Defrosting stop temp. ◊ *: Refrigerant
◊* Defrost
About indicator lights
◊on temp.: Temp. when controller on
◊off temp.: Temp. when controller off.
◊Comp. delay: Compressor output delay when
Temp.”display screen appears”F1″item, the system enters the system menusetting mode, then to page down and check all the parameter items by repeatedly pressing”SET”key. After entering the system menu, press”Ji.·and”T”key to modify the parameter value in the”Set Temp.”display screen, all the parameter indicator lights are off at this time

Under running status, press and hold”SET”key for 3s until the”on temp. “indicator light on, you can page down and check all the parameter items by repeatedly pressing”SET”key, and the parameter indicator light on with the accordingly parameter item is chosen. Under parameter checking mode, the parameter cannot be modified. If hold pressing the”SET”key for 3s or no key operations within 10s, system exit from the parameter checking mode, in the”Room Temp.”display screen, it appears the current storage temperature


Product detail pictures:

Factory Cheap Cold Room Chamber - MTC-5060 Operation Instruction  – Fland detail pictures

Factory Cheap Cold Room Chamber - MTC-5060 Operation Instruction  – Fland detail pictures

Factory Cheap Cold Room Chamber - MTC-5060 Operation Instruction  – Fland detail pictures


Related Product Guide:

To meet the customers' over-expected gratification , we have our robust crew to offer our over-all support which includes marketing, income, coming up with, production, excellent managing, packing, warehousing and logistics for Factory Cheap Cold Room Chamber - MTC-5060 Operation Instruction – Fland , The product will supply to all over the world, such as: Vietnam, Brazil, Guatemala, Our faith is to be honest first, so we just supply high quality products to our customers. Really hope that we can be business partners. We believe that we can establish long time business relationship with each other. You can contact us freely for more information and pricelist of our products !
  • We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Mabel from Cairo - 2018.06.28 19:27
    The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Jacqueline from European - 2017.05.02 11:33
    Write your message here and send it to us